Product Details:
|
Dimension: | 410mm×420mm×480mm | Weight: | 25 Kg |
---|---|---|---|
Operation Interface: | Color Touch Screen | Throughput Channel: | 1-32 |
Oscillation Mode: | Multi-mode Setting With Adjustable Frequency And Amplitude | Plate Type: | 96 Deep-well Plate |
Handling Volume: | 20-1000μL | Temperature Control: | Metal Bath Wrapped Heating |
High Light: | Purification automated dna extraction system,96 Deep Well Plate automated dna extraction system,automate express nucleic acid extraction system |
AiNA 32 Automatic Nucleic Acid Extraction Analyzer for Nucleic Acid extraction purification
Features:
Ease of Operation
Color touch screen with simple and clear graphical interface.
Safe and Reliable
Use of disposable extraction tubes, UV sterilization lamp, high-efficiency filtration system to prevent cross-contamination and ensure the biological safety.
High Efficiency and Flexibility
Compact, 32-channel throughput, fast extraction speed, high purified product rate.
Open and Customized
An open and customized platform, compatible for various extraction reagents in magnetic bead method.
Product parameters:
Dimension | 410mm×420mm×480mm |
Weight | 25kg |
Operation interface | Color touch screen |
Handling volume | 20-1000μL |
Throughput channel | 1-32 |
Plate type | 96 deep well plate |
Oscillation mode | Multi-mode setting with adjustable frequency and amplitude |
Temperature control | Metal bath wrapped heating |
Lysis temperature | Room temperature ~ 100℃ |
Washing temperature | Room temperature ~ 100℃ |
Sterilization | UV sterilization lamp, high-efficiency filtration system |
Program management | New establish, edit and delete |
Compatible reagent | Compatible for various extraction reagents in magnetic bead method |
Product description
AiNA 32 is an accurate laboratory machine for the extraction and purification of nucleic acids from human samples. Adopting magnetic bead separation technology, AiNA 32 can automatically complete the whole procedure including lysis, adsorption, cleaning, washing and recycling etc. It can handle up to 32 samples at the same time with ease of operation and high extraction efficiency, which make it widely used in scientific research, in vitro diagnostics, food safety, forensic and other fields.
Principle:
After the sample is lysed by the lysis solution,the lysed nucleic acid will specifically adsorbed by the magnetic beads. Through the cooperation of the washing solutionⅠ,washing solutionⅡ,elution buffer and magnetic rod,various impurities that are not specifically bound to the magnetic beads are removed,and the magnetic beads adsorbing the nucleic acid are separated from the lysis solution. Finally, removing the magnetic beads,the nucleic acid molecules are dissolved in the elution buffer.
Contact Person: Aikang-medical
Tel: 8613714396218